AO/Reichert Long-life POC Bulb [11143]
SKU
10010
This replacement bulb fits into the Longlife Project-o-chart models: Longlife Project-O-Chart 11083, Longlife Project-O-Chart 12084, Selectra Project-O-Chart 11075, Selectra Project-O-Chart 12030. American Optical and Reichert have merged so you may also see American Optical on your eye chart
Description
This replacement bulb fits into the Longlife Project-o-chart models: Longlife Project-O-Chart 11083, Longlife Project-O-Chart 12084, Selectra Project-O-Chart 11075, Selectra Project-O-Chart 12030. American Optical and Reichert have merged so you may also see American Optical on your eye chart projector.
Cleaning & Care
Be careful to avoid handling bulbs with your bare hands since the oils on your fingertips can cause inconsistencies in performance. If you do touch the bulb, it’s ok, just wipe it down with an alcohol swab. The bulbs can get hot! Let it cool down before you take it out of the equipment.
Warranty
This item may be returned as per our normal return policy. Don’t forget! You need to contact us for a return authorization number (RMA). Although rated life is not a warranty, this bulb is rated to last 2,000 hours under ideal conditions.
About Reichert
With a history of 185 years, Reichert® (Buffalo, NY, USA) continues to be a global leader in the design and manufacture of high-quality diagnostic instruments and equipment for ophthalmologists, optometrists, and retail eye care centers. The company's products are used for a wide range of applications, from common vision testing to diagnosing sight-threatening diseases such as glaucoma and macular degeneration. Inventors of the Lensometer®, Phoroptor®, and Non-Contact Tonometer, Reichert carries on its proud tradition by providing ground-breaking products including the highly acclaimed Tono-Pen®, Ocular Response Analyzer,® and ClearChart®.
- Also known as 11143
- For use by optometrists, ophthalmologists, and other eye care professionals
- Click on the specifications tab for more
Cleaning & Care
Be careful to avoid handling bulbs with your bare hands since the oils on your fingertips can cause inconsistencies in performance. If you do touch the bulb, it’s ok, just wipe it down with an alcohol swab. The bulbs can get hot! Let it cool down before you take it out of the equipment.
Warranty
This item may be returned as per our normal return policy. Don’t forget! You need to contact us for a return authorization number (RMA). Although rated life is not a warranty, this bulb is rated to last 2,000 hours under ideal conditions.
About Reichert
With a history of 185 years, Reichert® (Buffalo, NY, USA) continues to be a global leader in the design and manufacture of high-quality diagnostic instruments and equipment for ophthalmologists, optometrists, and retail eye care centers. The company's products are used for a wide range of applications, from common vision testing to diagnosing sight-threatening diseases such as glaucoma and macular degeneration. Inventors of the Lensometer®, Phoroptor®, and Non-Contact Tonometer, Reichert carries on its proud tradition by providing ground-breaking products including the highly acclaimed Tono-Pen®, Ocular Response Analyzer,® and ClearChart®.
Specifications
Reorder No. | 11143 |
Equipment Brand | American Optical/Reichert |
Equipment Models | Longlife Project-O-Chart 11803, 12084; Selectra Project-O-Chart 11075, 12030 |
Equipment Type | Eye Chart Projector |
Wattage | 20W |
Voltage | 6V |
Lumens | 570 lm |
Average Life | 2000 hrs |
Color Temperature | 3000K |
Shape | T2.5 |