Principio de la página

Retinoscopio de cabeza Welch Allyn 3.5V Elite [18245]

N.º de artículo 10589
Precio de venta recomendado $678
Precio $610.2
precio por Each
Antes de impuestos
En existencia
Each
The Welch Allyn 18245 Elite Streak Retinoscope Head is the clinical standard for streak retinoscopy in optometry and ophthalmology. It delivers 2.8 times the brightness of standard retinoscopes, a crossed linear polarizing filter to eliminate trial lens glare, and sealed optics for long-term

Descripción

The Welch Allyn 18245 Elite Streak Retinoscope Head is the clinical standard for streak retinoscopy in optometry and ophthalmology. It delivers 2.8 times the brightness of standard retinoscopes, a crossed linear polarizing filter to eliminate trial lens glare, and sealed optics for long-term reliability. Compatible with all Welch Allyn 3.5V power handles.

Compatibility
The Welch Allyn 18245 retinoscope head is compatible with all Welch Allyn 3.5V power handles including the NiCad Rechargeable Handle [71670], the Plug-In Rechargeable NiCad Handle [71000-A], the Convertible NiCad Handle [71000-C], and the Li-Ion Rechargeable Handle [71910].

Authorized distributor
Lite Source is an authorized Welch Allyn distributor. The 18245 purchased from Lite Source is a genuine OEM instrument backed by Welch Allyn's manufacturer warranty. We have supplied diagnostic instruments to optometry, ophthalmology, and general medical practices for over 40 years.

Replacement bulb
The Welch Allyn 18245 uses the 08200 series 3.5V halogen streak retinoscope bulb. Both the equivalent 08200-EQ and the OEM 08200-U are stocked and available. Keep a spare bulb on hand so an instrument change does not interrupt your examination schedule.

Also available
We carry the complete Welch Allyn retinoscope system including handles, fixation cards, and replacement bulbs. Browse our full Welch Allyn selection, chat with a live expert, or call us at 800-523-0860.

Especificaciones

Common Item No.
18245
Equipment Brand
Welch Allyn
Equipment Type
Retinoscope
Voltaje
3.5V
Product Brand
Welch Allyn/Hillrom/Baxter
Subtype
Head
GTIN
00732094087734
Country/Region of Origin Code
USA

Frequently asked questions

Is Lite Source an authorized Welch Allyn distributor?

Yes. Lite Source Inc. is an authorized Welch Allyn distributor. The Welch Allyn 18245 Elite Retinoscope Head purchased from Lite Source is a genuine OEM instrument eligible for Welch Allyn's manufacturer warranty. We have supplied Welch Allyn diagnostic instruments to medical practices across the United States for over 40 years.

What power handles are compatible with the Welch Allyn 18245 retinoscope head?

The Welch Allyn 18245 retinoscope head is compatible with all Welch Allyn 3.5V power handles including the NiCad Rechargeable Handle [71670], the Plug-In Rechargeable NiCad Handle [71000-A], the Convertible NiCad Handle [71000-C], and the Li-Ion Rechargeable Handle [71910].

What replacement bulb does the Welch Allyn 18245 Elite Retinoscope use?

The Welch Allyn 18245 Elite Retinoscope Head uses the 08200 series 3.5V halogen streak retinoscope bulb. Lite Source stocks both the equivalent 08200-EQ and the genuine OEM 08200-U.

Where can I find replacement parts for the Welch Allyn 18245 retinoscope?

Lite Source stocks replacement bulbs, compatible handles, and fixation cards for the Welch Allyn 18245 retinoscope. Browse the complete Welch Allyn parts and equipment selection or call us at 800-523-0860.

What should I check if my Welch Allyn 18245 retinoscope is not illuminating?

Check three things in order: confirm the retinoscope head is fully seated on the handle, confirm the battery is installed and fully charged, and confirm the 08200 bulb is fully seated in the socket. If the instrument still does not illuminate after checking all three, the bulb or battery may need to be replaced. Lite Source stocks both the 08200-EQ equivalent bulb and the OEM 08200-U. Call us at 800-523-0860 if you need help diagnosing the issue.

How do I replace the bulb in a Welch Allyn 18245 Elite Streak Retinoscope?

You will need: 08200-EQ equivalent or OEM 08200-U bulb, isopropyl alcohol swab.

Step 1 — Remove the retinoscope head. Detach the 18245 head from the power handle by gently rotating counterclockwise until it releases. Set the handle aside.

Step 2 — Access the bulb. With the head detached, the bulb socket is accessible inside the head assembly.

Step 3 — Remove the old bulb. Grip the old bulb by its base and pull it straight out of the socket. Do not touch the glass envelope with bare hands.

Step 4 — Prepare the new bulb. Handle the replacement 08200 bulb by its base only. If you accidentally touch the glass surface, wipe it with an isopropyl alcohol swab before installing. Skin oils cause uneven heating and premature failure.

Step 5 — Install the new bulb. Insert the new bulb straight into the socket and press firmly until fully seated. Do not force or angle the bulb during insertion.

Step 6 — Reattach and test. Reconnect the retinoscope head onto the handle. Switch on and confirm the streak is bright and well-defined. If it does not illuminate, check that the head is fully seated on the handle, the battery is installed and charged, and the bulb is fully seated in the socket. If the issue persists, the bulb or battery may need to be replaced.

Retinoscopio de cabeza Welch Allyn 3.5V Elite [18245]

N.º de artículo 10589
Precio de venta recomendado $678
Precio $610.2
precio por Each
Antes de impuestos
En existencia
Each
The Welch Allyn 18245 Elite Streak Retinoscope Head is the clinical standard for streak retinoscopy in optometry and ophthalmology. It delivers 2.8 times the brightness of standard retinoscopes, a crossed linear polarizing filter to eliminate trial lens glare, and sealed optics for long-term

Descripción

The Welch Allyn 18245 Elite Streak Retinoscope Head is the clinical standard for streak retinoscopy in optometry and ophthalmology. It delivers 2.8 times the brightness of standard retinoscopes, a crossed linear polarizing filter to eliminate trial lens glare, and sealed optics for long-term reliability. Compatible with all Welch Allyn 3.5V power handles.

Compatibility
The Welch Allyn 18245 retinoscope head is compatible with all Welch Allyn 3.5V power handles including the NiCad Rechargeable Handle [71670], the Plug-In Rechargeable NiCad Handle [71000-A], the Convertible NiCad Handle [71000-C], and the Li-Ion Rechargeable Handle [71910].

Authorized distributor
Lite Source is an authorized Welch Allyn distributor. The 18245 purchased from Lite Source is a genuine OEM instrument backed by Welch Allyn's manufacturer warranty. We have supplied diagnostic instruments to optometry, ophthalmology, and general medical practices for over 40 years.

Replacement bulb
The Welch Allyn 18245 uses the 08200 series 3.5V halogen streak retinoscope bulb. Both the equivalent 08200-EQ and the OEM 08200-U are stocked and available. Keep a spare bulb on hand so an instrument change does not interrupt your examination schedule.

Also available
We carry the complete Welch Allyn retinoscope system including handles, fixation cards, and replacement bulbs. Browse our full Welch Allyn selection, chat with a live expert, or call us at 800-523-0860.

Especificaciones

Common Item No.
18245
Equipment Brand
Welch Allyn
Equipment Type
Retinoscope
Voltaje
3.5V
Product Brand
Welch Allyn/Hillrom/Baxter
Subtype
Head
GTIN
00732094087734
Country/Region of Origin Code
USA

Frequently asked questions

Is Lite Source an authorized Welch Allyn distributor?

Yes. Lite Source Inc. is an authorized Welch Allyn distributor. The Welch Allyn 18245 Elite Retinoscope Head purchased from Lite Source is a genuine OEM instrument eligible for Welch Allyn's manufacturer warranty. We have supplied Welch Allyn diagnostic instruments to medical practices across the United States for over 40 years.

What power handles are compatible with the Welch Allyn 18245 retinoscope head?

The Welch Allyn 18245 retinoscope head is compatible with all Welch Allyn 3.5V power handles including the NiCad Rechargeable Handle [71670], the Plug-In Rechargeable NiCad Handle [71000-A], the Convertible NiCad Handle [71000-C], and the Li-Ion Rechargeable Handle [71910].

What replacement bulb does the Welch Allyn 18245 Elite Retinoscope use?

The Welch Allyn 18245 Elite Retinoscope Head uses the 08200 series 3.5V halogen streak retinoscope bulb. Lite Source stocks both the equivalent 08200-EQ and the genuine OEM 08200-U.

Where can I find replacement parts for the Welch Allyn 18245 retinoscope?

Lite Source stocks replacement bulbs, compatible handles, and fixation cards for the Welch Allyn 18245 retinoscope. Browse the complete Welch Allyn parts and equipment selection or call us at 800-523-0860.

What should I check if my Welch Allyn 18245 retinoscope is not illuminating?

Check three things in order: confirm the retinoscope head is fully seated on the handle, confirm the battery is installed and fully charged, and confirm the 08200 bulb is fully seated in the socket. If the instrument still does not illuminate after checking all three, the bulb or battery may need to be replaced. Lite Source stocks both the 08200-EQ equivalent bulb and the OEM 08200-U. Call us at 800-523-0860 if you need help diagnosing the issue.

How do I replace the bulb in a Welch Allyn 18245 Elite Streak Retinoscope?

You will need: 08200-EQ equivalent or OEM 08200-U bulb, isopropyl alcohol swab.

Step 1 — Remove the retinoscope head. Detach the 18245 head from the power handle by gently rotating counterclockwise until it releases. Set the handle aside.

Step 2 — Access the bulb. With the head detached, the bulb socket is accessible inside the head assembly.

Step 3 — Remove the old bulb. Grip the old bulb by its base and pull it straight out of the socket. Do not touch the glass envelope with bare hands.

Step 4 — Prepare the new bulb. Handle the replacement 08200 bulb by its base only. If you accidentally touch the glass surface, wipe it with an isopropyl alcohol swab before installing. Skin oils cause uneven heating and premature failure.

Step 5 — Install the new bulb. Insert the new bulb straight into the socket and press firmly until fully seated. Do not force or angle the bulb during insertion.

Step 6 — Reattach and test. Connect the retinoscope head back onto the handle. Switch on and confirm the streak is bright and well-defined. If it does not illuminate, check that the head is fully seated on the handle, the battery is installed and charged, and the bulb is fully seated in the socket. If the issue persists, the bulb or battery may need to be replaced.